Connecting the
mains cable
If no mains cable is connected, a mains cable that is suitable for the connection voltage
must be fitted before commissioning.
The ground conductor should be approx. 10 - 15 mm (0.4 - 0.6 in.) longer than the phase
conductors.
An illustration of the mains cable connection can be found in the following sections for
fitting the strain-relief device. To connect the mains cable, proceed as follows:
1
Remove the side panel from the device
2
Push the mains cable in far enough to make it possible to connect the ground con-
ductor and the phase conductors to the block terminal properly.
3
Fit ferrules to the ground conductor and phase conductors
4
Connect the ground conductor and phase conductors to the block terminal
5
Use the strain-relief device to secure the mains cable
6
Fit the side panel of the device
Fitting the strain-
relief device, TSt
2700c, single-
phase operation
1
3,5 Nm
2
3
2
N
L2
L1
4
43
EN
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...