Single-phase operation
Single-phase
operation
As an alternative to three-phase operation, the multivoltage variant (MV) of the power
source enables a welding operation with limited power or duration from just a single-
phase supply. The maximum possible welding power is limited due to the dimensioning
of the mains fuse protection, upon which the safety cut-out of the power source is
dependant.
If the mains cable has a 20 A or 30 A fuse, the FUS parameter may be changed to 20 A
or 30 A. Welding with a higher maximum power or for longer periods is therefore pos-
sible. The FUS parameter is in the level 2 Setup menu and can be set for a single-phase
supply as well as to a US setting (SEt parameter to US).
In order to use the power source in single-phase operation, the following prerequisites
must be fulfilled:
-
Correct single-phase power source supply in accordance with the chapter "Installa-
tion and commissioning," section "Connecting the mains cable" - "Fitting the strain-
relief device, single-phase operation."
The following table shows which mains voltages and fuse values limit the welding current
in single-phase operation:
Mains voltage
Fuse value
Welding current limitation
230 V
10 A
MIG/MAG welding:
max. 170 A; 100 A at 100%*
MMA welding:
max. 140 A; 100 A at 100%*
230 V
13 A
MIG/MAG welding:
max. 160 A; 150 A at 100%*
MMA welding:
max. 140 A; 120 A at 100%*
230 V
16 A
MIG/MAG welding:
max. 180 A; 145 A at 100%*
MMA welding:
max. 150 A; 130 A at 100%*
240 V
15 A
MIG/MAG welding:
max. 180 A; 145 A at 100%*
MMA welding:
max. 150 A; 125 A at 100%*
240 V
20 A
MIG/MAG welding:
max. 200 A; 160 A at 100%*
MMA welding:
max. 180 A; 140 A at 100%*
240 V
30 A
MIG/MAG welding:
max. 220 A; 175 A at 100%*
MMA welding:
max. 180 A; 140 A at 100%*
* The 100% values relate to welding with no time limits and without cooling breaks
The welding current data applies at an ambient temperature of 40°C (104°F).
At a mains voltage of 240 V and a fuse value of 30 A the maximum value of 220 A for the
MIG/MAG welding for instance is possible at a duty cycle of 40 %.
49
EN
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...