Mains voltage (U
1
)
3 x 400 V
Max. effective primary current (I
1eff
)
14.5 A
Max. primary current (I
1max
)
23 A
Mains fuse
35 A slow-blow
Mains voltage (U
1
)
3 x 460 V
Max. effective primary current (I
1eff
)
12.7 A
Max. primary current (I
1max
)
20.1 A
Mains fuse
35 A slow-blow
Mains voltage tolerance
-10 % /+ 15 %
Mains frequency
50 / 60 Hz
Cos phi (1)
0.99
Max. permitted mains impedance Z
max
at PCC
1)
77 mOhm
Recommended earth-leakage circuit breaker
Type B
Welding current range (I
2
)
MIG/MAG
Rod electrode
10 - 350 A
10 - 350 A
Welding current at 10 min / 40 °C (104 °F)
40 %
350 A
60 %
300 A
100 %
250 A
Output voltage range according to standard character-
istic (U
2
)
MIG/MAG
Rod electrode
14.5 - 38.5 V
20,4 - 35,0 V
Open circuit voltage (U
0
peak / U
0
r.m.s)
60 V
Apparent power at 400 V AC
15.87 kVA
Degree of protection
IP 23
Type of cooling
AF
Insulation class
B
Overvoltage category
III
Pollution level according to IEC60664
3
Safety symbols
S, CE, CSA
Dimensions l x w x h
747 x 300 x 497 mm
29.4 x 11.8 x 19.6 in.
Weight
36 kg
79.4 lb.
Max. shielding gas pressure
5 bar
72.52 psi
Coolant
Original Fronius
Wire feed speed
1 - 25 m/min
40 - 980 ipm
Wire drive
4-roller drive
112
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...