WARNING!
Whenever the cleaning device and connected system components are supplied
with voltage and/or compressed air, a risk of serious injury exists from:
▶
rotating cleaning cutter / rotating cleaning brush
▶
lifting device moving up/down
▶
extending/retracting gas nozzle clamping device
▶
activated wire cutter
▶
flying parts (shavings, etc.)
▶
compressed air/parting agent mixture escaping from the parting-agent injec-
tion nozzles
If work has to be performed on the cleaning device while it is being supplied with
voltage and/or compressed air:
▶
keep your body, especially your hands, face, hair, any objects and all clothing
away from the cleaning cutter / cleaning brush, lifting device, gas nozzle
clamping device, wire cutter and parting-agent injection nozzles
▶
wear ear protection
▶
wear protective goggles with side protection
CAUTION!
A cleaning cutter / cleaning brush that has become very hot through use can
cause severe burns.
Before handling the cleaning cutter / cleaning brush, allow cleaning cutter /
cleaning brush to cool to room temperature (+25°C, +77°F).
Ensuring that
the cleaning
device is depres-
surised
Attempt to briefly activate the cleaning device without any compressed air sup-
ply to check whether the cleaning device is depressurised. Proceed as follows:
1
Take protective measures:
-
The cleaning cutter / cleaning brush, lifting device, gas nozzle clamping
device, wire cutter and parting-agent injection nozzles could start up.
Therefore keep your body, especially your hands, face and hair, any ob-
jects and all clothing away from the parts referred to above
-
wear ear protection
-
wear protective goggles with side protection
2
Ensure that the cleaning device has been disconnected from the compressed
air supply
On the Robacta Reamer Alu Edition, Robacta Reamer Alu 3000upm:
3
Briefly turn the "Cleaning" screw on the cleaning device 90° to the right, then
turn it straight back to its original position
-
If the cleaning device does not respond to the turning of the screw, the
cleaning device is depressurised
-
If the cleaning device responds to the turning of the screw, the cleaning
device is still connected to a compressed air supply.
If this is the case, you must disconnect the cleaning device from the com-
pressed air supply and check again that the cleaning device is depressurised
before starting work
76
Summary of Contents for Robacta Reamer Alu 3000upm
Page 2: ......
Page 12: ...12...
Page 13: ...General 13...
Page 14: ...14...
Page 23: ...Controls connections and mechan ical components 23...
Page 24: ...24...
Page 30: ...30...
Page 31: ...Installation and commissioning 31...
Page 32: ...32...
Page 40: ...Attach the spatter tray retainer as shown 3 40...
Page 67: ...Care maintenance and disposal 67...
Page 68: ...68...
Page 73: ...Troubleshooting 73...
Page 74: ...74...
Page 80: ...80...
Page 81: ...Technical data 81...
Page 82: ...82...
Page 85: ...Appendix 85...
Page 86: ...86...