Adjusting the Robacta Reamer Alu Edition lifting
device
Adjusting the
lifting device
(1)
(1)
(2)
(2)
1
Remove protective covering (1)
2
Ensure that the lifting device is in
its lowest position
3
Loosen screw (2) on the lifting
device
4
Move the welding torch to the
cleaning position
(4)
(4)
(4)
(2)
(2)
(2)
(5)
(5)
(5)
(3)
(3)
(3)
(6)
(6)
(6)
1/3
1/3
1/3
2/3
2/3
2/3
5
Push the lifting device (3) by hand into its highest position and hold in place
6
Manually push cleaning motor (4) and cleaning brush to the cleaning posi-
tion
-
see diagram (5) - correct adjustment
-
see diagram (6) - incorrect adjustment
7
Fix cleaning motor (4) in this position in the lifting device (3) - tighten screw
(2) on the lifting device
8
Carry out function test - push lifting device by hand to its highest position
-
Check that lifting device is adjusted correctly - see diagram (5). If the
correct adjustment is not given, readjust the lifting device
9
Fit the protective covering to the cleaning device in its original position
46
Summary of Contents for Robacta Reamer Alu 3000upm
Page 2: ......
Page 12: ...12...
Page 13: ...General 13...
Page 14: ...14...
Page 23: ...Controls connections and mechan ical components 23...
Page 24: ...24...
Page 30: ...30...
Page 31: ...Installation and commissioning 31...
Page 32: ...32...
Page 40: ...Attach the spatter tray retainer as shown 3 40...
Page 67: ...Care maintenance and disposal 67...
Page 68: ...68...
Page 73: ...Troubleshooting 73...
Page 74: ...74...
Page 80: ...80...
Page 81: ...Technical data 81...
Page 82: ...82...
Page 85: ...Appendix 85...
Page 86: ...86...