Starting up the Robacta Reamer Twin parting
agent nebuliser
Starting up the
parting agent
nebuliser
NOTE!
Only use "Robacta Reamer" parting agent (item number 42,0411,8042).
The composition of this parting agent is designed specifically for the cleaning
device. If other manufacturers' products are used, trouble-free operation cannot
be guaranteed.
NOTE!
Use the parting agent - spray unit option to achieve sufficient wetting of the en-
tire Twin welding torch interior.
With the parting agent - spray unit option, the parting agent is sprayed through
the blow out line directly into the welding torch interior.
1
Open the sealing plug (1)
2
Fill with "Robacta Reamer" parting agent using the filling funnel (2)
3
Close the sealing plug (1)
NOTE!
If the spray amount is not sufficient after starting up the cleaning device, in-
crease it as required:
▶
by adjusting the spray time using the robot control - a spray time of ~ 0.7
seconds is recommended
▶
or by using the parting agent adjuster (4): remove the safety clamp (3), use a
screwdriver to set the parting agent adjuster (4) so that the welding torch in-
terior is coated with a thin layer of parting agent (0.2-0.5 ml) after the spray-
ing action is complete
3
2
1
(1)
(1)
(4) (3)
(2)
49
EN
Summary of Contents for Robacta Reamer Alu 3000upm
Page 2: ......
Page 12: ...12...
Page 13: ...General 13...
Page 14: ...14...
Page 23: ...Controls connections and mechan ical components 23...
Page 24: ...24...
Page 30: ...30...
Page 31: ...Installation and commissioning 31...
Page 32: ...32...
Page 40: ...Attach the spatter tray retainer as shown 3 40...
Page 67: ...Care maintenance and disposal 67...
Page 68: ...68...
Page 73: ...Troubleshooting 73...
Page 74: ...74...
Page 80: ...80...
Page 81: ...Technical data 81...
Page 82: ...82...
Page 85: ...Appendix 85...
Page 86: ...86...