91
g
Operating Status
LED
Position of Operating Status LED on the in-
verter
Depending on the operating status, the
Operating Status LED assumes different
colors:
A list of most status codes, the corresponding status information, their status causes and
repair measures can be found in the chapter "Troubleshooting and Maintenance," section
"Status Diagnosis and Troubleshooting."
(13)
Output bar (not active during setup)
indicates the output power fed into the grid at a given moment - regardless of the
display mode chosen. The screen displays % of the maximum possible output
power of your solar inverter
Item
Function
Operating Status LED Explanation
Steady green
The LED stays lit after the automatic startup phase of the invert-
er as long as power is being fed into the grid.
It indicates problem-free operation of the photovoltaic system.
Flashing green
The photovoltaic system is working correctly, a status code is on
the display.
When a status code is shown, rectify the relevant condition by
going to the "Maintenance and Service" chapter, "Status Diag-
nosis and Troubleshooting" section. The status code can be ac-
knowledged by pressing the "Enter" key.
Steady orange
The inverter enters an automatic startup phase as soon as the
solar modules are delivering sufficient power after sunrise.
Flashes orange
A warning is shown on the display
or
the inverter has been set to standby operation in the Setup
menu (= manual shutoff of operation).
The next day, operation will resume automatically.
During the time the LED flashes orange, operation can be re-
sumed manually at any time (see section "The Setup Menu")
Steady red
General status: the respective status code is shown on the
screen
Remains dark
There is no connection to the solar modules,
no solar module power due to darkness.
Summary of Contents for IG Plus 100 V-1
Page 2: ...0...
Page 4: ...2...
Page 10: ...8...
Page 16: ...14...
Page 17: ...General Information...
Page 18: ......
Page 20: ...18 Safety symbols Risk of serious injury and damage due to incorrect operation...
Page 24: ...22...
Page 25: ...Installation and Startup...
Page 26: ......
Page 76: ...74 1 2 6 x 18...
Page 80: ...78 Closing Fronius IG Plus Closing Fronius IG Plus 1 1 3 2 1 1 2 3 2 4 1 3...
Page 89: ...Operation...
Page 90: ......
Page 126: ...124...
Page 127: ...Troubleshooting and Maintenance...
Page 128: ......
Page 146: ...144 Disconnect DC wire Disconnect AC wire 8 9...
Page 150: ...148...
Page 151: ...Appendix...
Page 152: ......
Page 164: ...162...
Page 165: ...163 g...
Page 167: ...165 g...