6 Servicing
DANGER
When working on the unit with a live power supply:
Serious injury possible due to automatic startup!
When working on the system or in the store, it is essential that the five safety
directives are followed:
❒ Disconnect all poles on all sides
❒ Secure so that it cannot be switched on again
❒ Check that there is no power
❒ Earth and short circuit
❒ Cover any adjacent live parts and limit area of risk
6.1 Maintenance schedule
2
4
8,9
3
1
5
6
7
10
W
M
VJ
BF
W
M
VJ
BF
W = weekly, M = monthly, Q = quarterly, F = prior to each fill of the store
No.
Component
Int.
Operation
1
Motor / gears
W
❒ Carry out a general visual inspection of the drive motor
➥ No major oil leaks should be visible.
2
Gravity shaft / safety switch
M
Function test of the safety switch:
❒ Open the inspection cover of the gravity shaft
➥ The system should switch off immediately.
❒ Check the inlet area for material build-up and clean where necessary.
❒ Close gravity shaft cover
❒ Check fault message on the controller
Servicing
6
Maintenance schedule
Installation Instructions TGR 110/150/200 | M1390116_en
39