4.3.2 Assembling the gears and feeder trough
NOTICE! The mitre gear is pre-assembled on the bracket. Tighten all screw
connections during installation!
❒ Fit the closed trough with ceramic fibre seal to the open trough
- 4x hexagonal screw M12 x 35 mm
- 4x spacer washers M12
- 4x nuts M12
➥ Check the alignment of the flange plates!
❒ Place the mitre gear and trough channel on the floor
❒ Secure the open trough to the mitre gear
- 4x hexagonal screw M16 x 35 mm
- 4x spacer washer M16
❒ Fit the gear supports to the mitre gear as shown
- 4x hexagonal screw M16 x 35 mm
- 4x spacer washer M16
➥ Do not fully tighten the screws yet!
❒ When the unit has been screwed together, insert it through the hole in the wall on
the store side
4
Assembly
Assembling the torsion arm agitator