2.6 Residual risks
The discharge system has been designed and built to comply with the relevant safety
directives. Nevertheless by the nature of its operation and function, there are residual
risks which cannot be eliminated completely.
DANGER
When working on the unit with a live power supply:
Serious injury possible due to automatic startup!
When working on the system or in the store, it is essential that the five safety
directives are followed:
❒ Disconnect all poles on all sides
❒ Secure so that it cannot be switched on again
❒ Check that there is no power
❒ Earth and short circuit
❒ Cover any adjacent live parts and limit area of risk
DANGER
When working on rotary agitator arms:
Serious injuries possible from pre-tensioned rotary agitator arms!
When working on the rotary agitator arms, you must therefore:
❒ Loosen the tension in the rotary agitator arms, or secure them so they cannot
spring back in an uncontrolled way before dismantling them
CAUTION
If unauthorised fuel types are used:
Non-standard fuels can cause stiffness and block the system, resulting in the
failure/breakage of components.
Therefore:
❒ Only use fuels specified in the "Permitted uses" section of these operating
instructions.
Safety