5 | Servicing the system
42
B1300122_en | Operating instructions Lambdamat LM 800-1000
5.5 Maintenance tasks
r
Regular cleaning of the boiler extends its life and is a basic requirement for smooth
running.
r
Recommendation: use an ash vacuum for cleaning.
5.5.1 Periodic inspection and cleaning
approx. 1,000 h
"Cleaning the ash transfer chamber" [
"Cleaning the flue gas recirculation (FGR) duct"
"Checking the heat exchanger" [
"Cleaning the flue gas temperature sensor" [
"Cleaning the area under the moving grate" [
approx. 3000h:
"Cleaning the combustion air fan" [
"Checking the underpressure controller" [
"Checking the seal of the cleaning port doors"
"Checking the combustion chamber overpressure
"Checking the seal of the reversing chamber door"
"Cleaning the FGR blower fan" [
"Checking the position and seal of the burning and
"Cleaning the induced draft fan" [