4 | Operating the system
24
B1300122_en | Operating instructions Lambdamat LM 800-1000
4.2.1 Loading of fuel for a partially emptied store with rotary agitator
If there is still sufficient fuel in the fuel store (the rotary agitator head is completely
covered with fuel and the rotary agitator arms / spring blades are not extended), the store
can be filled.
r
Load the fuel at the filling opening
4.2.2 Loading fuel into an empty fuel store with a rotary agitator
If the rotary agitator head is already free from material and the rotary agitator arms /
spring blades are extended, the feeder unit must be active until the rotary agitator arms /
spring blades have fully retracted.
For combined drive:
r
Activate “Extra heating” mode in the quick selection menu
For separate drive:
r
Tap “On” in “Bunker filling rotary agitator” during manual operation
Ä
The rotary agitator head runs for approx. 3 minutes
r
Load a small quantity of wood chips and wait until the arms / spring blades are
touching the head of the rotary agitator (approx. 2 revolutions)
r
Only then should you load the remaining material