2 | Safety
16
B1300122_en | Operating instructions Lambdamat LM 800-1000
2.7 Emergency procedure
2.7.1 Overheating of the system
If the system overheats and the safety devices fail to operate, proceed as follows:
NOTICE! Do not under any circumstances switch off the main switch or disconnect
the power supply.
r
Keep all the doors on the boiler closed
r
Open all mixing valve taps, switch on all pumps.
Ä
The Froling heating circuit control takes on this function in automatic operation.
r
If a third-party controller is used, carry out the appropriate measures to activate the
mixer taps and pumps manually.
r
Leave the boiler room and close the door
r
Increase heat consumption by turning on all radiators and other appliances
r
Open any thermostatic valves on the radiator and ensure sufficient heat dissipation
from the rooms
If the temperature does not drop:
r
Contact the installer or Froling customer services
2.7.2 Smell of flue gas
DANGER
If you smell flue gas in the boiler room:
Inhaling toxic flue gas can be fatal!
If you smell flue gas in the room where the boiler is installed:
r
Keep all the doors on the boiler closed
r
Shut down the boiler according to procedure
r
Ventilate the room where the boiler is installed
r
Close the fire door and doors to living areas
Recommendation:
Do not install smoke alarms and carbon monoxide detectors near the
system.
2.7.3 Fire in the system
DANGER
In case of fire in the system:
Risk of death by fire and poisonous gases
Emergency procedure in case of fire:
r
Leave the boiler room
r
Close the doors
r
Inform the fire department