Servicing the system | 5
B1300122_en | Operating instructions Lambdamat LM 800-1000
51
Cleaning the fireclay elements
"Periodic inspection and cleaning" [
NOTICE! In order to avoid damage to the burning chamber temperature sensor, it
should be removed before starting work in the burning chamber
r
Note the position of the burning chamber temperature sensor
Ä
Use sticky tape (1) for example
r
Loosen the screws on the bracket (2)
r
Carefully remove the burning chamber temperature sensor
Ä
if necessary, clean carefully
r
When all tasks in the burning chamber have been completed, replace the burning
chamber temperature sensor
Ä
Note the marking (e.g. sticky tape)
r
Open the reversing chamber door
r
Open the two cleaning port doors
r
Carefully clean the bottom of the heat exchanger and the top of the upper vault using
the cleaning brush (A)
r
Carefully clean the side walls with the flat scraper (B)
r
Check the fireclay elements for wear