Operating the system | 4
B1300122_en | Operating instructions Lambdamat LM 800-1000
27
4.2.6 Loading fuel in a store space with a sliding floor discharge unit
NOTICE! Compliance with the maximum dumping height of the fuel according to
the assembly instructions of the sliding floor discharge system is mandatory
Filling the storeroom without moving the slide rods
r
Use the filling opening to add the fuel
Ä
The system does not have to be shut down during the filling process
Filling the storeroom by moving the slide rods
Only move the slide rods in compliance with the following instructions:
r
Fuel quantity of at least 30 cm on the slide rods
r
Do not drive on the wedges and longitudinal members of the sliding floor discharge.
TIP: A guiding device for driving inside the storeroom must be provided, e.g. gates
must be positioned appropriately
r
Hydraulic unit switched off and secured to prevent accidental restart
r
When driving across the slide rods, the steering movements of the vehicle must be
kept to a minimum
NOTICE! Driving onto the slide rods may compact the fuel and thus causing the
sliding floor discharge unit to move sluggish