3 Technology
3.1 Dimensions
B
α
D1
L1
L2
L3
D
Item
Description
GAR 110
GAR 150
L1
Length of open trough
⇨
L2
Length of closed trough
Transfer c connected trough
L3
Length of discharge screw
Determined during planning of the fuel store
D
Diameter, rotary agitator
⇨
D1
Diameter, screw
Ø 110 mm
Ø 150 mm
B
Width of trough channel
140 mm
200 mm
α
Gradient angle
0 – 10° (wood chips)
0 – 3° (pellets)
NOTICE
Operating the discharge system with a gradient angle > 10°
The mitre gear can break due to insufficient lubrication!
When installing the discharge system, you should therefore ensure:
❒
When operating with wood chips do not exceed a gradient angle α of 10°
❒
When operating with pellets do not exceed a gradient angle α of 3°
➥
The rotary agitator should always be fitted as flat as the place of
installation allows
Technology
3
Dimensions
Installation and Operating Instructions GAR 110 / 150 | M2060120_en