G2 Core
MPC8260 PowerQUICC II Family Reference Manual, Rev. 2
2-24
Freescale Semiconductor
Program
00700
A program exception is caused by one of the following exception conditions, which
correspond to bit settings in SRR1 and arise during execution of an instruction:
• Illegal instruction—An illegal instruction program exception is generated when
execution of an instruction is attempted with an illegal opcode or illegal
combination of opcode and extended opcode fields (including PowerPC
instructions not implemented in the processor core), or when execution of an
optional instruction not provided in the processor core is attempted (these do not
include those optional instructions that are treated as no-ops).
• Privileged instruction—A privileged instruction type program exception is
generated when the execution of a privileged instruction is attempted and the
MSR register user privilege bit, MSR[PR], is set. In the processor core, this
exception is generated for
mtspr
or
mfspr
with an invalid SPR field if SPR[0] = 1
and MSR[PR] = 1. This may not be true for all processors that implement the
PowerPC architecture.
• Trap—A trap type program exception is generated when any of the conditions
specified in a trap instruction is met.
Floating-point
unavailable
00800
A floating-point unavailable exception is caused by an attempt to execute a
floating-point instruction (including floating-point load, store, and move instructions)
when the floating-point available bit is cleared (MSR[FP] = 0).
Decrementer
00900
The decrementer exception occurs when the most significant bit of the decrementer
(DEC) register transitions from 0 to 1. Must also be enabled with the MSR[EE] bit.
Reserved
00A00–00BFF —
System call
00C00
A system call exception occurs when a System Call (
sc
) instruction is executed.
Trace
00D00
A trace exception is taken when MSR[SE] = 1 or when the currently completing
instruction is a branch and MSR[BE] = 1.
Floating-point
assist
00E00
Not implemented.
Reserved
00E10–00FFF —
Instruction
translation
miss
01000
An instruction translation miss exception is caused when the effective address for an
instruction fetch cannot be translated by the ITLB.
Data load
translation
miss
01100
A data load translation miss exception is caused when the effective address for a
data load operation cannot be translated by the DTLB.
Data store
translation
miss
01200
A data store translation miss exception is caused when the effective address for a
data store operation cannot be translated by the DTLB, or when a DTLB hit occurs,
and the changed bit in the PTE must be set due to a data store operation.
Instruction
address
breakpoint
01300
An instruction address breakpoint exception occurs when the address (bits 0–29) in
the IABR matches the next instruction to complete in the completion unit, and the
IABR enable bit (bit 30) is set.
System
management
interrupt
01400
A system management interrupt is caused when MSR[EE] = 1 and the SMI input
signal is asserted.
Reserved
01500–02FFF
—
Table 2-5. Exceptions and Conditions (continued)
Exception
Type
Vector Offset
(hex)
Causing Conditions
Summary of Contents for MPC8250
Page 90: ...MPC8260 PowerQUICC II Family Reference Manual Rev 2 lxxxviii Freescale Semiconductor...
Page 94: ...MPC8260 PowerQUICC II Family Reference Manual Rev 2 I 4 Freescale Semiconductor...
Page 118: ...Overview MPC8260 PowerQUICC II Family Reference Manual Rev 2 1 24 Freescale Semiconductor...
Page 236: ...Reset MPC8260 PowerQUICC II Family Reference Manual Rev 2 5 14 Freescale Semiconductor...
Page 274: ...60x Signals MPC8260 PowerQUICC II Family Reference Manual Rev 2 7 18 Freescale Semiconductor...
Page 548: ...MPC8260 PowerQUICC II Family Reference Manual Rev 2 IV 8 Freescale Semiconductor...
Page 1072: ...ATM AAL2 MPC8260 PowerQUICC II Family Reference Manual Rev 2 32 10 Freescale Semiconductor...
Page 1356: ...MPC8260 PowerQUICC II Family Reference Manual Rev 2 Index 28 Freescale Semiconductor U U Index...