Model UR-2 <Controlling from an external device>
0
1
2 ~ 12
13, 14
15
ETX
03h
20h, 20h
02h
63h/73h
STX
c/s
Command/status code (checksum)
Command/status code (hex)
Checksum
Byte
Checksum calculation range
Command configuration (data arrangement)
Each command corresponds to a key function assigned to a front panel key and parallel remote pin. No
multiple press, simultaneous press or SHIFT press is supported. Commands are sent directly. By enter-
ing text from Tera Term, etc., according to the Command list shown later, you can simply control the
unit.
[Byte 0]: Start byte
Every series of commands of the unit starts with
start byte (02h).
[Byte 1]: Command/status byte
Selects command or status request. The lowercase
"c" (63h) indicates a command, while the lower-
case "s" (73informationh) indicates a status.
[Byte 2 through 12]: Command/status code
These eleven bytes are reserved for parameters re-
garding a command or status request.
If the status information is less than eleven bytes, a
space (20h) is inserted.
[Byte 13 and 14]: Checksum
Sums hexadecimal data of byte 1 through byte 12
and represents the lower two digits of the result in
hexadecimal.
<Example>: PLY (PLAY command)
63 (c) + 50 (P) + 4C (L) + 59 (Y) = 158 ->58
byte 13: “5” -> 35h
byte 14: “8” -> 38h
[Byte 15]: End byte
Each data is ended with the end byte (03h).
REC
c
STOP
c
PLAY
c
REW
c
c
c
c
c
c
FFWD
SKIP<<
SKIP>>
ABS 0
REC END
STX
1
2
3
4
5
6
7
8
9
10
11
12
CHK CHK ETX
STX
1
2
3
4
5
6
7
8
9
10
11
12
CHK CHK ETX
HEX
02
63
52
45
43
20
20
20
20
20
20
20
20
33
44
03
02
63
53
54
50
20
20
20
20
20
20
20
20
35
41
03
02
63
50
4C
59
20
20
20
20
20
20
20
20
35
38
03
02
63
52
45
57
20
20
20
20
20
20
20
20
35
31
03
02
63
46
57
44
20
20
20
20
20
20
20
20
35
34
03
02
63
53
4B
2B
20
20
20
20
20
20
20
20
34
43
03
02
63
53
4B
2D
20
20
20
20
20
20
20
20
32
45
03
02
63
41
42
30
20
20
20
20
20
20
20
20
31
36
03
02
63
52
45
44
20
20
20
20
20
20
20
20
33
45
03
D
A
8
1
4
C
E
6
E
3
5
5
5
4
2
2
1
3
R
S
P
R
F
S
S
A
R
E
T
L
E
W
K
K
B
E
C
P
Y
W
D
+
-
O
D
ASCII (A blank is a space.)
0
c
1
c
2
c
3
c
c
c
c
c
c
4
5
6
7
8
STX
1
2
3
4
5
6
7
8
9
10
11
12
CHK CHK ETX STX
1
2
3
4
5
6
7
8
9
10
11
12
CHK CHK
ETX
HEX
02
63
4B
59
30
20
20
20
20
20
20
20
20
33
37
03
02
63
4B
59
31
20
20
20
20
20
20
20
20
33
38
03
02
63
4B
59
32
20
20
20
20
20
20
20
20
33
39
03
02
63
4B
59
33
20
20
20
20
20
20
20
20
33
41
03
02
63
4B
59
34
20
20
20
20
20
20
20
20
33
42
03
02
63
4B
59
35
20
20
20
20
20
20
20
20
33
43
03
02
63
4B
59
36
20
20
20
20
20
20
20
20
33
44
03
02
63
4B
59
37
20
20
20
20
20
20
20
20
33
45
03
02
63
4B
59
38
20
20
20
20
20
20
20
20
33
46
03
7
8
9
A
B
C
D
E
F
3
3
3
3
3
3
3
3
3
K
K
K
K
K
K
K
K
K
Y
Y
Y
Y
Y
Y
Y
Y
Y
0
1
2
3
4
5
6
7
8
ASCII (A blank is a space.)
c
9
K
Y
9
c
10+
K
0
+
0
4
9
0
02
63
4B
59
39
20
20
02
63
4B
30
2B
20
20
20
20
20
20
20
20
20
20
20
20
20
20
34
30
03
30
39
03
Correct receipt
r
Not remotable
s
Error
r
Error (BUSY)
r
STX
1
2
3
4
5
6
7
8
9
10
11
12
CHK CHK ETX STX
1
2
3
4
5
6
7
8
9
10
11
12
CHK CHK ETX
HEX
02
72
53
54
50
20
20
20
20
20
20
20
20
35
39
03
02
73
52
4E
47
20
20
20
20
20
20
20
20
35
41
03
02
72
45
52
52
20
20
20
20
20
20
20
20
35
42
03
02
72
42
47
59
20
20
20
20
20
20
20
20
35
34
03
9
A
B
4
6
5
5
5
S
R
E
B
T
N
R
G
P
G
R
Y
ASCII (A blank is a space.)
* Controlled by ASCII characters.
* When the unit receives a command, it sends the status information.
If the command is remotely controllable, the unit adds "r" to the command status byte and sends back the
same character string as the command. If the command is not remotely controllable, the unit adds "s" to the
command status byte and sends back the same character string as the command.
Command control list
<Commands related to transport keys>
<Commands related to numeric keys>
<Response>
Summary of Contents for UR-2
Page 95: ......