8. Troubleshooting
Problem
Possible cause
Solution
RUN-LED
on the CAN
connector flashes
continuously.
Switch on the CAN
Connector, page 21
u
Make sure that the Bus Master is
configured correctly.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
ERROR-LED on
the CAN connector
flashes.
Switch on the CAN
Connector, page 21
u
Make sure that the CAN Interface
is configured correctly. See
Commissioning the CAN Interface,
page 54
u
Make sure that the Bus Master is
configured correctly.
u
Make sure that the bit rate of the
CAN bus is configured correctly.
u
Check the CAN cable for damage.
Replace damaged cables.
u
Make sure that the CAN cable is
connected correctly.
u
Do a firmware update. See
.
8.4.2 Troubleshooting CAN Object 0x2000
TIP
The number of the sub-object corresponds to the channel
number.
Table 47: Troubleshooting CAN Object 0x2000
Problem
Possible cause
Solution
64 / 80
MDE0835_4-10_1.3.x_5.0_Blackbird
OECD_(6CH, CNO)-en-us
© fos4X 2020
Summary of Contents for Blackbird OECD MDE0835