3. Product Description
Table 19: LED on the Ethernet connector.
State
Power-LED
Status-LED
On
Network connection present
-
Off
No network connection present
No network traffic
Flashing
Network traffic
3.4.1.4
LEDs and Switch on the CAN Connector
There are 3 LEDs on the CAN connector. One LED is not used.
Figure 7: LEDs and Switch on the CAN Connector
1
Switch for terminating resistor
2
Run-LED (green)
3
Error-LED (red)
4
LED not in use
Switch for terminating resistor
The CAN connector has a 120 Ohm terminating resistor. The terminating resistor can
be activated and deactivated via the switch (1). In the right position, the terminating
resistor is active.
Run-LED
Table 20: Run-LED on the CAN Connector
State
Device state
Description
On
Operational
■
After booting, if
auto-
operational
is active
■
Set by Bus-Master
© fos4X 2020
MDE0835_4-10_1.3.x_5.0_Blackbird
OECD_(6CH, CNO)-en-us
21 / 80
Summary of Contents for Blackbird OECD MDE0835