Environmental specifications
Hardware installation
FortiMail™ Secure Messaging Platform Version 4.0 Patch 1 Install Guide
22
Revision 2
If required to fit into a rack unit, remove the rubber feet from the bottom of the FortiMail
unit.
Environmental specifications
•
Operating temperature:
32 to 104°F (0 to 40°C)
If you install the FortiMail unit in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient
temperature. Therefore, make sure to install the equipment in an environment
compatible with the manufacturer's maximum rated ambient temperature.
•
Storage temperature:
-13 to 158°F (-25 to 70°C)
•
Humidity:
5 to 90% non-condensing
•
Air flow:
For rack installation, make sure that the amount of air flow required for safe
operation of the equipment is not compromised.
For free-standing installation, make sure that the FortiMail unit has sufficient clearance
on each side to allow for adequate air flow and cooling.
Mounting the FortiMail unit
FortiMail-100 and FortiMail-100C
Adhere the rubber feet included in the package to the underside of the FortiMail unit, near
the corners of the unit if not already attached.
Place the FortiMail unit on any flat, stable surface. Ensure the FortiMail unit has sufficient
clearance on each side to ensure adequate airflow for cooling.
If you remove the rubber feet, you can alternatively mount the FortiMail unit in a 2U-tall
space in any standard 19-inch rack unit.
FortiMail-400
The FortiMail unit can be placed on any flat surface, or mounted in a standard 19-inch rack
unit.
When placing the FortiMail unit on any flat, stable surface, ensure the FortiMail unit has
sufficient clearance on each side to ensure adequate airflow for cooling.
For rack mounting, use the mounting brackets and screws included with the FortiMail unit.
To install the FortiMail unit into a rack
1
Attach the mounting brackets to the side to the unit so that the brackets are on the front
portion of the FortiMail unit.
The following photos illustrate how the brackets should be mounted. Note that the
screw configuration may vary.
Caution:
To avoid personal injury, you may require two or more people to mount the
FortiMail unit in the rack.