87
20. Reboot and Initialize
20-1. Rebooting System
(1) Press the MENU button, then press the 7/SETUP button to display the SETUP top menu.
(2) Turn F1 to select SYSTEM, then press F1 or the PAGE DOWN button to open the [SETUP-
SYSTEM] menu.
(3)
Turn F1 to select REBOOT. Press the ENT/STORE button in the MENU/DIRECT
PATT/EVENT/KEYPAD block to reboot the system.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>TIME >INIT >
REBOOT
20-2. System Initialization
To initialize the system settings, follow the procedure below.
(1) Press the MENU button, then press the 7/SETUP button to display the SETUP top menu.
(2) Turn F1 to select SYSTEM, then press F1 or the PAGE DOWN button to open the [SETUP-
SYSTEM] menu.
(3) Turn F1 to select INIT, then press F1 or the PAGE DOWN button to display the
[SETUP-SYSTEM-INIT] menu.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>TIME >
INIT
>REBOOT
(4) Turn F1 to select SETUP(expSYS) , then press F1 to initialize the switcher setup data except
the system data.
SYSTEM : INIT : LOAD : : 1/1
INIT : >CURRENT : =
LAST
: :
CURRENT:
Resets settings for the background, KEYER, PinP, DSK and MATT.
SETUP(expSYS): Resets the SETUP menu except [SETUP-SYSTEM] menu.
CUR&SETUP:
Resets settings including CURRENT and SETUP(expSYS) above.
FACTORY:
Resets settings including CUTTENT and SETUP including
[SETUP-SYSTEM] menu.
See section 5-3. "How to Return Settings to Default" for initializing menus.
See section 17-5. "Loading Event at Start-up" for how to load the desired setting at system
startup.
Summary of Contents for HVS-300HS
Page 1: ...HVS 300HS Digital Video Switcher HVS 30OU Operation Unit 1st Edition Rev 1 OPERATION MANUAL...
Page 104: ......