83
19-2. Selecting Reference Signal
The switcher provides reference input, its loop-through and output connectors in the GENLOCK
section on the rear panel.
19-2-1. To Set Reference Input
(1) Press the MENU button, then press the 7/SETUP button to display the SETUP top menu.
Turn F1 to select SYSTEM, then press F1 or the PAGE DOWN button to open the
[SETUP- SYSTEM] menu.
(2) Turn F1 to select REF I/O, then press F1 or the PAGE DOWN button to open the
[SETUP - SYSTEM - REF IN] menu.
(3) Turn F1 to select a reference signal to be input to the switcher between Black Burst and
Tri-level Sync.
SYSTEM : TYPE : : 1/2
REF IN : =BB : :
19-2-2. To Set Reference Output
(1) Press the PAGE DOWN button in the [SETUP-SYSTEM-REF IN] menu to go to the
[SETUP- SYSTEM-REF OUT] menu.
(2) Turn F1 to select a reference signal to be output from the switcher between Black Burst
and Tri-level Sync.
(3) You can adjust the horizontal phase of the reference signal under the
H PHS
item and the
vertical phase under the
V PHS
item.
SYSTEM : TYPE : H PHS : V PHS : : 2/2
REF OUT : =BB : =0 : =0 : :