![Fogo Montanha E601 Instruction Manual Download Page 9](http://html1.mh-extra.com/html/fogo-montanha/e601/e601_instruction-manual_2314728009.webp)
9
the correct and safe operation of the stove. The flue is extremely important when fitting the stove. Be sure to
consult authorised specialists about the connection to ensure compliance with local building regulations. Bear in
mind the following:
The appliance door must be closed when in use and also when not in use.
There must be an adequate supply of fresh air when the appliance is in use.
Fire safety measures relating to combustible or temperature sensitive floor surfaces:
A fire resistant, non-combustible covering must be fitted under and around the stove. This must be at least
15cm thick.
No combustible materials should be stored underneath the appliance (e.g., firewood).
The safety distances from combustible or temperature sensitive objects, given in the table of technical
characteristics, must be adhered to.
4.4. Auxiliary table installation (PA1090G051 or PA1090G049)
To perform a greenfield installation, two height-adjustable auxiliary tables are available to facilitate the work of
installing the equipment. A larger table (item PA1090G051) for fitting sizes E901/E801/E909/E809 and a smaller
table (item PA1090G049) for fitting sizes E701/E601/E709/E609/E609H.
The table is adjustable in height and has 2 components to regulate the depth in order to fix it to the back wall, it
also has holes in the bottom of the legs to facilitate the fixation to the floor, Figure 1.
Figure 1 - Installation of auxiliary table
It is very important that the table is level, both in depth and width, this will facilitate the extraction of the
equipment on the guides increasing their life time. To level the table, it is necessary to adjust the adjustable legs in
height, although the floor is uneven.
Fixing to the wall and the floor will depend on the material they are made of. Fixing must be very firm, because the
insert has a considerable weight, for this reason, the following configurations are recommended according to the
material where the table will be fixed:
PA1090G051 - Auxiliary table for equipment Models:
E901/E801/E909/E809
PA1090G049 - Auxiliary table for equipment Models:
E701/E601/E709/E609/E609H
Summary of Contents for E601