36
2.
Remove the smoke channel (B) by pushing it towards the top of the stove (1). Then move the smoke channel
forward (2), it is loose and remove it by moving it downwards (3), Figure 43.
Figure 43 – Removing the smoke circuit
3.
To reinstall the smoke circuit, repeat all the procedures in reverse order. Note that the damper shaft (C) is
placed in the groove in the smoke channel (B). To check that the smoke channel is installed correctly, pull the
damper and check that the damper flap (D) moves, see Figure 44.
Figure 44 – Fitting of the smoke circuit system
Removal of insulating material (vermiculite)
When cleaning the chimney, it may be necessary to remove the vermiculite insulation material. This can only be
done after removing the smoke deflector and the smoke circuit.
Very important:
Take extra care when removing this material as it is fragile.
Before removing the insulating material “vermiculite”, remove the ash tray and ash drawer.
1.
Remove the ash deflector by shifting upwards, see Figure 45.
1
2
3
3
7
C
B
D