31
Model
Distance X
E901
3 mm
E801
8 mm
E701
7 mm
E601
3 mm
E909
5 mm
E809
8 mm
E709
7 mm
E609
5 mm
Table 1 - Distance from the optimum firing point
In hot and to add more wood:
1.
Fully open the combustion air control, “Primary air”.
2.
Opening the hot air outlet handle, “Smoke flap”.
3.
Open the door slowly.
4.
With the poker arrange the coals evenly on the bottom of the ash tray and the vermiculite sheets.
5.
Put small, new wood on the coals, then larger wood.
6.
Close the door and let it burn until the stove is very hot and the embers are glowing.
7.
Close the hot air outlet handle, “Smoke flap”.
8.
Close combustion air control, “Primary air”.
9.
Choose the position to be used at the door.
Note:
Do not carry firewood above vermiculite walls.
* Check that there is sufficient air circulation in the room where the installation is to be carried out, otherwise the
equipment will not work properly. For this reason, check if there are other heating appliances which consume air
for their operation (e.g., gas appliances, fireplaces, etc.). We do not recommend operating these appliances at the
same time;
* The door should only be opened during refuelling. The normal conditions of use of the equipment imply that the
door should be kept closed;
* When atmospheric conditions are so adverse as to cause strong disturbance to the stove's smoke extraction (in
particular very strong winds), it is advisable not to use the stove;
* It is recommended to use firewood with a length between 26 and 30 cm. In this way it is possible to place the
firewood longitudinally or transversally to the base of the combustion chamber.