Issue/Rev. 0.2 (12/12)
MN0M023 • Page 147
Device Functions Proline Promass 83 10 Block
SPECIAL
FUNCTION
10.2
Group BATCHING FUNCTION
10.2.1
Function group CONFIGURATION
SPECIAL FUNCTION
H
BATCHING FUNCTION
HCA
CONFIGURATION
720
Function description
SPECIAL FUNCTION
o
BATCHING FUNCTION
o
CONFIGURATION
BATCH SELECTOR
(7200)
Use this function to select a batching specification. There are six different batching
specifications available by means of which different batchings can be defined.
Options:
BATCH # 1 (or the name which was defined for batching specification 1 in the function
BATCH NAME (7201) )
BATCH # 2 (or the name which was defined for batching specification 2 in the function
BATCH NAME (7201) )
BATCH # 3 (or the name which was defined for batching specification 3 in the function
BATCH NAME (7201) )
BATCH # 4 (or the name which was defined for batching specification 4 in the function
BATCH NAME (7201) )
BATCH # 5 (or the name which was defined for batching specification 5 in the function
BATCH NAME (7201) )
BATCH # 6 (or the name which was defined for batching specification 6 in the function
BATCH NAME (7201) )
Factory setting:
BATCH #1
!
Note!
• By selecting a batching specification and its related settings (explained below), up to 6
different batchings
can be preconfigured and selected as necessary.
• All the following functions in this function group, as well as the functions in the
function groups VALVE PARAMETER (722) and SUPERVISION (724) are assigned to
the batching specification selected here.
• All the settings in the following functions of this function group are valid only for the
batching specification selected in the function BATCH SELECTOR (7200). In other
words, the entry or option is assigned to the batching specification currently selected
(e.g. in the factory setting BATCH # 1).
BATCH NAME
(7201)
Use this function to assign a specific name to the batching specification.
User input:
max. 8-character text, permissible: A-Z, 0-9
Factory setting:
Name of batching specification (depends on selection in the function BATCH SELECTOR
(7200), e.g. “BATCH # 1”).
!
Note!
Once an entry has been made (e.g. “BEER 33”), the batch name (BEER 33) appears in the
home position when selecting the quantity and the name of the batching specification
(e.g. “BATCH # 1”) no longer appears.