Issue/Rev. 0.2 (12/12)
MN0M023 • Page 143
Device Functions Proline Promass 83 10 Block
SPECIAL
FUNCTION
SQR. EXPANSION
COEFFICIENT TARGET
FLUID
(7006)
!
Note!
This function is not available unless one of the following was selected in the DENSITY
FUNCTION function (7000):
• % MASS / % VOLUME
• %-BLACK LIQUOR
Use this function to enter the fluid-specific square expansion coefficient for the carrier
fluid for nonlinear temperature curves. This value is required for temperature-
compensated calculation of the target fluid content in a
two-phase fluid.
User input:
5-digit floating-point number, including unit and sign
Factory setting:
0.0000 e–6 [1/K
2
]
LINEAR EXPANSION
COEFFICIENT
(7007)
!
Note!
This function is not available unless one of the following was selected in the DENSITY
FUNCTION function (7000):
• °BAUME < 1 SG
• °BAUME > 1 SG
• °API
• °PLATO
• °BALLING
• °BRIX
Use this function to enter the fluid-specific linear expansion coefficient (for linear
temperature curves), to calculate the temperature-compensated density functions.
User input:
5-digit floating-point number, including unit and sign
Factory setting:
0.5000 e–3 [1/K]
SQR. EXPANSION
COEFFICIENT
(7008)
!
Note!
This function is not available unless one of the following was selected in the DENSITY
FUNCTION function (7000):
• °BAUME < 1 SG
• °BAUME > 1 SG
• °API
• °PLATO
• °BALLING
• °BRIX
Use this function to enter the fluid-specific square expansion coefficient (for nonlinear
temperature curves), to calculate the temperature-compensated density functions.
User input:
5-digit floating-point number, including unit and sign
Factory setting:
0.0000 e–6 [1/K
2
]
Function description
SPECIAL FUNCTION
o
DENSITY FUNCTIONS
o
CONFIGURATION