Comark RF500A/AP Service Manual
Appendix E – RF500A/AP Hidden Commands
Utility Commands
The following commands all required the same input method, using a web browser type the following:
•
http://your-ip-address/cgi-bin/msg?msg=command-name
Where:
•
your-ip-address is the current IP address of the RF500A/AP
•
command-name selected from the list below
emberlog2
This command displays the log for the RF software running on the RF500A/AP, the excerpt below shows an example of
a normal log file detailing version number and entrance and exit points for the software. Errors the software detects will
be clearly stated in this log.
emberlog2-/home/ember/Ember/Cipher_Debug.txt----------------------------------------------/Thu Sep 15 10:34:10 2011 /----------------
Starting Cipher-host Session Version: 0 2.00R.Time Was Wed Sep 7 11:21:22 2011
networkUp has been set false 0 N/A.Time Was Wed Sep 7 11:21:22 2011
networkUp has been set false by emberStackStatusHandler 0 N/A.Time Was Wed Sep 7 11:22:22 2011
networkUp has been set true by emberStackStatusHandler 0 N/A.Time Was Wed Sep 7 11:22:30 2011
Have Been Asked to Quit 0 N/A.Time Was Wed Sep 14 09:52:42 2011
Important messages within this file are explained below.
Message
Comments
Unexpected Packet 1 Sequence Number....
An RF packet has arrived out of sequence which may
contain corrupt data, the system will exit if this condition
is detected to preserve data integrity.
Tired to transmit but emberstatus returned !
EMBER_NETWORK_DOWN!
The RF network stack has mysteriously gone down, the
system will self recover from this event.
Too Many RNAP errors will now exit...
The RF software has detected multiple comm port errors
and has decided to shutdown as there is likely a hardware
fault.
Have Been Asked to Quit...
The software has been asked to quit by the webserver.
ERROR I THINK I'VE GONE DEAF NOT HEARD
FROM MESHERS OR ANYTHING NEED RESET
**CODE
The system has stopped receiving RF data, this message
indicates the system has meshers and hence should be
receiving information within 10 minutes. This will cause
the RF sub-system to reset.
ERROR I THINK I'VE GONE DEAF NOT HEARD
FROM ANYTHING NEED RESET **CODE
The system has stopped receiving RF data, this message
indicates the system has not got any meshers. This will
cause the RF sub-system to reset.
17 November 2011