III. Trouble Shooting
With highly reliable design, the BE6000 ultrasonic flowmeter has a low failure rate. However, problems may
occur as a result of unskillful handling, setting errors or working in an extremely undesirable working
condition. For this reason, the meter is equipped with a self-diagnostic function. Problems detected are
displayed in time order in code form on the upper right corner of the LCT screen. Hardware malfunctions,
though generally checked after power is on, can also be detected (part of them) while the device is working
normally. Information about “stop working” problems caused by wrong settings or undesirable working
conditions can also be displayed, so users can locate the problems quickly and solve the problems according
to the solutions offered in the following two tables in time.
There are two kinds of error displayed in BE6000:
-
Error messages are displayed during self-test after the power is switched on. After entering the
measurement mode, if there is an error, “*F” will be displayed at the top left corner of the screen. Check the
information being displayed and take specific steps according to the following tables. If problems persist,
contact your BE6000 distributor.
-
Errors about the specific signal received or wrong settings can be displayed by the M08
window in error code form. Errors and solutions are listed in the following tables;
Power-On self-test information, Causes and Solutions
LCD Display
Causes
Solution
ROM Parity Error
System ROM illegal or in error
Contact the manufacturer.
Stored Data Error
Stored Data Error
Restart the instrument or contact the
manufacturer.
Handshaking Error
Hardware handle wrong, system will
reset.
Restart.
SCPU Fatal Error
Fatal error in sub CPU circuit
Restart or contact the manufacturer.
Timer Slow Error Timer Fast
Error
System clock is wrong.
Contact the manufacturer.
CPU or Interruption error,
retry
Main CPU is wrong.
Restart
System RAM Error
System RAM has problems.
Restart or contact the manufacturer.
Time or Batt Error
System time chip error
Restart or contact the manufacturer.
When pressing the keys, no
response from screen, no
display or disorderly display
Mis-operation, poor cable contact on
the panel
Soft Reset. Check whether the cables
on the panel are contacted well.
PRN Time Over
Printer wrong or wrong connection.
Examine printer or cable.