![Flomotion Systems be6000 series Installation And Operation Manual Download Page 24](http://html1.mh-extra.com/html/flomotion-systems/be6000-series/be6000-series_installation-and-operation-manual_2306731024.webp)
BE6000 Ultrasonic Flow Meter O&M Manual
Flomotion Systems, Inc. ~ FlomotionSystems.com
24
avoid this, set the lowest signal strength threshold to about 30~40, below which the system stop
measurement because the pipe is deemed to be empty.
Measurement Unit (M30)
The following options are provided;
0. Metric
1. English
The default is Metric.
Flow Rate Units(M31)
The following flow units and time units are available;
Flow Units
0. Cubic Meters (m
3
)
5. Cubic Feet (cf)
1. Liters (l)
6. (American) Barrels
2. (American) Gallons
7. Imperial Barrels
3. Imperial Gallons
8. Oil Barrels (ob)
4. Million Gallons
Time Units
/hour /day
/min
/sec
•
Totalizer Units(M32)
Select totalizer units. The available unit options are the same as those found in M31. The user can select
units as required. Factory default is cubic meters.
•
Totalizer Multiplier Options(M33)
The totalizer multiplier acts as the function to increase the totalizer indicating range. Meanwhile, the totalizer
multiplier can be applied to the positive totalizer, negative totalizer and net totalizer at the same time. The
followings options are available;
0. X 0.001 (1E-3)
4. X10
Measurement Units In
0.
Metric
Flow Rate Units
m3/h
Totalizer Multiplier
m3/h
Totalizer Units
Cubic Meters (m
3
)