Save & add voice annotation
: The voice annotation tool will be displayed.
◦
Save & add sketch
: The sketch annotation tool will be displayed.
◦
Save & add any annotation
: The annotation tool menu will be displayed.
•
Image resolution
: This setting defines the resolution of the images captured by the
camera. Available options are
Normal
and
UltraMax
. For more information, see sec-
tion 14.1.4
•
Video compression
: This setting defines the storage format for video clips. Available
options are:
◦
Mpeg (*.mpeg)
: MPEG recordings cannot be edited after the file has been saved.
◦
Radiometric storage (*.csq)
: A CSQ file supports full radiometry but is only sup-
ported by FLIR Systems software. The file does not include any visual image infor-
mation. With this setting, only the image modes
Thermal
and
Macro
are supported
when recording video.
•
Photo as separate JPEG
: For the
Thermal MSX
,
Thermal
, and
Picture in picture
im-
age modes, a visual image is always saved in the same JPEG file as the thermal im-
age. Enabling this setting saves an extra low-resolution visual image as a separate
JPEG file.
•
Digital camera
: This setting is used to turn on/off the digital camera. Turning off the
digital camera can for example be required in restricted areas and in confidential (e.g.
doctor/patient) situations. When the digital camera is off, the images modes
Thermal
MSX
and
Picture in picture
are disabled.
•
File naming format
: This setting defines the naming format for new image/video files.
The setting has no impact on already saved files in the archive. Available options are:
◦
DCF
: DCF (Design rule for Camera File system) is a standard that specifies the
naming method of image files (and much more). With this setting, the name of a
saved image/video file will be FLIRxxxx, where xxxx is an incremental counter. Ex-
ample: FLIR0001. (When the counter has reached 9999, the file name will change
to IR_yyyyy.jpg.)
◦
Date prefix
: A prefix will be added to the filename, including the date and the text
“IR_” for images and “MOV_” for videos. Examples: IR_2015-04-22_0002 and
MOV_2015-04-22_0003. The date format will follow the
Date & time format
setting,
see section 28.1.4
, page 106.
Note
With the
Date prefix
setting, the files may not automatically be detected by
third-party applications.
•
Delete all saved files...
: This displays a dialog box where you can choose to perma-
nently delete all the saved files (images and videos) from the memory card or to can-
cel the delete action.
28.1.4
Device settings
•
Language, time & units
: This submenu includes settings for a number of regional
parameters:
◦
Language
.
◦
Temperature unit
.
◦
Distance unit
.
◦
Time zone
.
◦
Date & time
.
◦
Date & time format
.
•
Continuous autofocus
: This setting is used to enable/disable continuous autofocus.
•
Display settings
: This submenu includes the following settings:
◦
Screen rotation
: This setting defines if the orientation of the overlay graphics will
change according to how you hold the camera.
Note
You can also enable/disable screen rotation on the swipe-down menu. For
more information, see section 11.4
, page 28.
#T559954; r. AT/65353/65353; en-US
106
Summary of Contents for 72501-0101
Page 2: ......
Page 3: ......
Page 5: ...User s manual FLIR T10xx series T559954 r AT 65353 65353 en US v ...
Page 6: ......
Page 14: ......
Page 43: ...Screen elements 11 T559954 r AT 65353 65353 en US 29 ...
Page 125: ...Mechanical drawings 30 See next page T559954 r AT 65353 65353 en US 111 ...
Page 134: ...Digital I O connection diagram 32 See next page T559954 r AT 65353 65353 en US 120 ...
Page 135: ......
Page 136: ...CE Declaration of conformity 33 See next page T559954 r AT 65353 65353 en US 122 ...
Page 137: ......
Page 144: ... T559954 r AT 65353 65353 en US 130 ...
Page 145: ......