16 Advanced functions
FLUXUS F401
16.3 Totalizers
105
UMFLUXUS_F401V2-1EN, 2020-06-12
The totalizer value will be displayed in the upper line (here: the volume which has passed
the measuring point in positive flow direction since the activation of the totalizers).
• Press ENTER while a totalizer is displayed to toggle between the display of the totalizers
for both flow directions.
• Select the command
→Clear totalizer
in the upper line to reset the flow totalizers
to zero.
• Press ENTER.
Automatic display toggling
The automatic toggling of the totalizer display between positive and negative flow direc
-
tion can be set.
• Enter a time interval between 0 (off) and 5 s.
• Press ENTER.
Totalizer storing
It is possible to store the currently displayed totalizer only or to store one value for each
flow direction.
• Select
Special Funct.\SYSTEM settings\Storing\Quantity Storage
.
• Press ENTER.
• If
one
is selected, only the value of the totalizer currently displayed will be stored. This
can apply for the positive and negative totalizer.
• If
both
is selected, the values of the totalizers for both flow directions will be stored.
• Press ENTER.
Totalizer behavior after the measurement is stopped
The totalizer behavior when the measurement is stopped or after a reset of the transmit
-
ter is set in the menu item
Special Funct.\SYSTEM settings\Measuring\
Quantity recall
.
• If
on
is selected, the values of the flow totalizers will be stored and used for the next
measurement.
• If
off
is selected, the flow totalizers will be reset to zero.
• Press ENTER.
Special Funct.\SYSTEM settings\Measuring\Toggle totalizer
Special Funct.\SYSTEM settings\Storing\Quantity Storage
Special Funct.\SYSTEM settings\Measuring\Quantity recall