27
32. Using a spray bottle of approved sanitizer
solution, spray end of the 9-Tube Assembly
and allow it to sanitize for at least 1 minute.
33. Carefully align the pins of the Syrup Line
Manifold with the Syrup Line Connector and
insert the end of the 9-Tube Assembly fully
into the Coupler.
34. Push the Coupler Nut into the Coupler Body
and rotate the Coupler Body until motion
stops to secure.
35. Install the cap on the manifold.
36. Prime the syrup system as instructed in the
next section “Priming the Syrup System.”
Priming the Syrup System
Priming the syrups is necessary when first
installing the flavors, after the Clean-In-Place
procedure, when an individual flavor or multiple
flavors remain idle for more than 72 hours, and
when changing flavors. Only the syrup lines
directly involved will require this process.
1. From the Touchscreen main menu, press
the SETUP key in the upper left corner.
Enter the password if required.
2. Select MAINTENANCE.
3. Press the PRIME SYRUP PUMP key.