44
Winterizing the Unit
If you will not be using your Flavor Burst
®
system during the off-season or other extended
periods of time, you should winterize the
TS 44BEV system as a precautionary practice
to avoid damage or undesirable syrup build-up
in the unit.
NOTE:
YOU DO NOT NEED TO USE
ANTIFREEZE SOLUTION IN THIS SYSTEM
WHEN WINTERIZING THE UNIT.
1. Perform the entire Clean-In-Place
procedure,
except…
a.
DO NOT perform Step 25 (do not
reconnect the Syrup Bag Connectors to
the syrup bags).
b.
DO NOT perform Steps 33 (do not
assemble or install the Blending
Assembly)
c.
DO NOT perform Step 34 (do not prime
the syrup lines).
2. Place both 9-Tube Assembly lines inside a
container.
3. Remove each syrup bag from its tray and
store as directed on the label.
4. Empty the Sanitizer Tank and return the
tank to the unit.
5. With the Sanitizer Tank empty, press the
INJECTOR FLUSH key until all sanitizer
solution is removed from the sanitizer line.
6. From the Touchscreen main menu, press
the SETUP key in the upper left corner.
Enter the password if required.
7. Press SPOUT A MAINTENANCE (or
SPOUT B MAINTENANCE if the syrup line
dispenses from Spout B).
Summary of Contents for TS 44BEV
Page 7: ...6 General System Overview Figure 1 ...
Page 12: ...11 PAGE INTENTIONALLY LEFT BLANK ...
Page 13: ...12 Blending Assembly and Related Parts Figure 3 ...
Page 15: ...14 Syrup Pump and Related Parts Figure 4 ...
Page 17: ...16 Sanitizer Pump and Related Parts Figure 5 ...
Page 21: ...20 Spare Parts Kit Figure 7 ...
Page 22: ...21 PAGE INTENTIONALLY LEFT BLANK ...
Page 26: ...25 PAGE INTENTIONALLY LEFT BLANK ...