5. Place the Adapter and o-rings in approved
sanitizer solution for at least 1 minute.
6. Remove each part from the sanitizer
solution and place them on a sanitary tray to
air dry.
7. Lube the black o-rings and install them in
their respective positions on the Adapter.
8. Clean the freezer door and spout according
to manufacturer’s instructions.
9. Set the Adapter on a flat, clean surface, and
then place the freezer door spout upright
onto the Adapter. Rock the freezer door
forward to snap the Adapter into place.
10. Return the freezer door to the freezer.
Replacing Blending Head O-Rings
The Blending Head o-rings are wear items and
will need to be replaced periodically. Always
keep spares of these items on hand in the
Spare Parts Kit for replacement.
1. Mix approved detergent with warm water
according to m
anufacturer’s instructions.
Also prepare approved sanitizer solution
according to manufacturer’s instructions.
2. Remove the worn o-rings from the Blending
Head. A small tool may be needed to
remove the two o-rings in the syrup line
opening.
3. Brush and clean all exposed surfaces of the
Blending Head with detergent water. Use a
small brush to ensure that the syrup orifices
are clear of any residual syrup.
4. Place the Blending Head and the new
replacement o-rings in an approved
sanitizer solution and soak for 1 minute.
Summary of Contents for TS 44BEV
Page 7: ...6 General System Overview Figure 1 ...
Page 12: ...11 PAGE INTENTIONALLY LEFT BLANK ...
Page 13: ...12 Blending Assembly and Related Parts Figure 3 ...
Page 15: ...14 Syrup Pump and Related Parts Figure 4 ...
Page 17: ...16 Sanitizer Pump and Related Parts Figure 5 ...
Page 21: ...20 Spare Parts Kit Figure 7 ...
Page 22: ...21 PAGE INTENTIONALLY LEFT BLANK ...
Page 26: ...25 PAGE INTENTIONALLY LEFT BLANK ...