33
Primary Fault:
Motor Control Module
Action:
Replace Motor Control Module
253
Smart Pump Over Current
The motor control Module has detected that the smart pump is drawing high current.
Primary Fault:
Pump stator winding short circuited
Action:
Check the resistance of the pump stator at the motor controller end of the
harness, resistance per Phase: 8.1Ω +/- 10% (16.2Ω +/- 10% Phase to
phase).
If faulty recheck the pump stator resistance at the Smart Pump. If
resistance is correct replace harness assembly but if still faulty replace pump.
254
Motor Control Version to Old
The Motor Control Module software version is too old for the display to support.
Primary Fault:
Motor Control Module
Action:
Replace Motor Control Module