13
d 02: Last User Warning Wash Cycle Position
The Wash Cycle position of the last user warning is displayed via the screen
Output Displayed
on Screen
Cycle
Position
00
01
02
03
Agitation
04
05
Rinse
06
Spin
d 03: Fault Code of Last Fault (if within the last 8 Wash Cycles)
Sometimes referred to as the detailed fault code. The fault data is output via
the display this will relate to a fault code as detailed in the
Fault Codes
section. If
000
is displayed then there has been no fault codes occur in the
last 8 cycles.
d 04: Cycle Count at Last Fault
The cycle count at which the last fault occurred is displayed via the screen
which will display the 100’s, 10’s & 1’s when all 3 segments are on and the
10,000’s & 1,000’s when only 2 segments are on with the displayed output
toggling between the 2 screens every 2 seconds.
E.g. For a cycle count of 1010 cycles
2 second later
Represent 100’s, 10’s & 1’s. &
10,000’s & 1,000’s =01,010 cycles
0 1 0
0 1