14
d 05: Cycle Position at Last Fault
The Wash Cycle position of the last fault is displayed via the screen.
Output Displayed
on Screen
Cycle Position
00
01
02
03
Agitation
04
05
Rinse
06
Spin
d 06: Water Temperature (Degrees C)
The Wash Temperature at the thermistor in
O
C is displayed via the screen
which is multiplied by 2
d 07: Cycle Count
The total number of Wash Cycles is displayed via the screen which will
display the 100’s, 10’s & 1’s when all 3 segments are on and the 10,000’s &
1,000’s when only 2 segments are on with the displayed output toggling
between the 2 screens every 2 seconds.
E.g. For a cycle count of 1010 cycles
2 second later
Represent 100’s, 10’s & 1’s. &
10,000’s & 1,000’s =01,010 cycles
Note: The wash cycle count is only incremented at the end of the spin
cycle
.
0 1 0
0 1