28
137
Motor loss of a Phase
The Motor Control Module has detected the loss of one of the phases of the motor. Possible causes of
this fault are: Faulty motor harness, an open circuit winding of motor or faulty motor controller.
Primary Source:
Wiring
Action:
Measure/check the motor harness, connectors and motor for continuity. This
can be done by taking a resistance measurement between phases of the
motor harness at the Motor Control Module end. Nominal resistance should
be around 39
Ω
.
Secondary Source:
Motor.
Action:
Remove Stator and measure / check the resistance of each winding which is
approximately 19.5
Ω
.
Tertiary Source:
Motor Control Module.
Action:
If the primary and secondary checks pass inspection, then replace the Motor
Control Module.
160.
Bowl Engaged In Agitate
The bowl has re-engaged itself during agitate.
Primary Source:
Mechanical.
Action:
1) Check that the rotating bowl assembly is not jammed to the agitator with
any foreign object that may be caught under the agitator skirt.
2) Check that the clutch teeth are not locked together with dirt, lint, etc.
3) Make sure the bowl is not overloaded with too many clothes.
4) If none of the above appears to be at fault, then check the air bell at the
bottom of the inner bowl for leaks.
Secondary Source:
Installation (drain) set up
Action:
Check that the drain hose is fitted into the drain caddy and extends no more
than 20 mm from the end. Check if fitted to a stand pipe that the drain hose is
not pushed down to far.
Tertiary Source:
Motor Control Module.
Action:
If the machine is empty of water at fault, it is possible that the pump circuit is
faulty and has caused a pump out during wash. This would cause the bowl to
re-engage during agitate and the Motor Control Module to display this fault.
Replace Motor Control Module.
220.
EEPROM Model Map Not Programmed
On power up, the Motor Control Module has detected a fault in its memory.
Primary Fault:
Motor Control Module.
Action:
Change Motor Control Module.
221
Motor Control Module Fault
The motor control has encountered a RAM check error
Primary Fault:
Motor Control Module.
Action:
Change Motor Control Module.
222
Motor Control Module Fault
The motor control has encountered a Stack error
Primary Fault:
Motor Control Module.
Action:
Change Motor Control Module.
223
Motor Control Module Fault
The motor control has encountered a program counter error
Primary Fault:
Motor Control Module.
Action:
Change Motor Control Module.