Chapter V Functional Parameter TableHigh-performance Universal Inverter User Manual
— 28 —
FC
name
description
Factory value
attribute
6: The FDT1 was detected by the frequency level
7: The FDT2 was detected by the frequency level
8: Frequency reaches
9: Running at zero speed
10: Upper limit frequency reaches
11: Lower limit frequency reaches
12: Ready to run
13: Pre-excitation in the field
14: Overload alarm
15: Under-load alarm
16: Simple PLC stage is completed
17: Simple PLC cycle is completed
18: Set the record value to arrive
19: Specify that the marked value arrives
20: External fault
22: Running time arrival
23: Communication virtual terminal output
07-02
HDO
terminal
output
function
selection
0
○
07-03
K 1 relay output
function selection
1
○
07-04
K 2 relay output
function selection
5
○
07-05
AO1
output
function selection
0: Run frequency
1: Set the frequency
2: Given the frequency of the slope
3: Run speed
4: Output current (2 times the rated value of the
frequency converter)
5: Output current (2 x motor rating)
6: Output voltage
7: Output power
8: Set torque
9: Output torque
10: Simulate the AI1 input values
11: Simulate the AI2 input values
12: Simulate the AI3 input values
13: High-speed pulse HDI input value
14: Communication Setpoint output
15: Keep
22: Torque current (3 times the motor rating)
4
○
07-07
HDO pulse output
function selection
0
○
07-08
AO1 output limit
-100.0%~(07-10)
0.0%
07-09
Corresponding
value of the lower
output limit of
0.00~10.00V
0.00V
○