Chapter V Functional Parameter TableHigh-performance Universal Inverter User Manual
— 16 —
FC
name
description
Factory value
attribute
combination
1: Frequency source B
2: frequency source A + frequency source B
3: frequency source A-frequency source B
4: Maximum value of both: MAX (A, B)
5: Minimum value of both: MIN (A, B)
00-08
Keyboard preset
frequency
0.00Hz
~
(00-08)
50.00Hz
○
00-09
Motor operation
direction
0: The direction is the same
1: The opposite direction
2: No reversal
0
●
00-10
maximun-frequen
cy
00-09
~
630.00Hz
50.00Hz
●
00-12
upper
limiting
frequency
00-10
~
(00-08)
50.00Hz
●
00-14
Lower
limit
frequency
0.00Hz
~
(00-09)
0.00Hz
●
00-15
carrier frequency
1.0
~
15.0K Hz
Model
determination
○
00-16
Zero
frequency
output selection
0: No output
1: There is output
2: DC brake output (size from 05-11)
0
○
00-17
Acceleration time
0
0.0
~
3600.0s
Model
determination
○
00-18
Slow down time 0 0.0
~
3600.0s
Model
determination
○
00-19
Industry
application macro
selection
0~65535
0
○
01 Set of motor parameters
01-01
Automatic
measurement of
the
motor
parameters
0: No function
1: Dynamic testing
2: Stationary Test 1
3: Stationary Test 2
0
●
01-02
The motor is rated
power
0.1
~
1000.0K W
Model
determination
●