Chapter V Functional Parameter TableHigh-performance Universal Inverter User Manual
— 30 —
FC
name
description
Factory value
attribute
08-01
MF K / JOG key
function selection
0: No function
1: Point up and run the JOG
2: Shift-based key (SHIFT)
3: Forward / reverse switch
4: Clear the UP / DOWN setting
5: Free parking
6: Run command source switch in sequence
(08-02)
1
●
08-02
The MF K key runs
the
command
source switching
0: Keyboard control terminal controls the
communication control
1: Keyboard control and terminal control
2: Keyboard control and communication control
3: Terminal control and communication control
0
○
08-03
The STOP / RESET
key function
0: Only valid for the panel controls
1: Effective for both panel and terminal control
2: Effective for both panel and communication
control
3: Effective for all control modes
0
○
08-04
Restore
factory
parameters
0: No operation
1: Restore the default values
2: Clear the fault record
3: Keyboard lock
0
●
08-05
Keyboard number
control settings
0000~1223
Individual bit: Frequency enables selection
The 0: / Key and the encoder are valid
1: Only the / key is valid
2: Only, the encoder
3: / Both the key and the encoder are invalid
Ten digits: Frequency control selection
0: Set is valid for keyboard numbers only
1: All frequency modes are valid
2: Invalid for multiple speed when multiple speed
is preferred
Hundred bits: action selection when shutdown
0: Set effectively
1: Effective during operation and cleared after
shutdown
2: Valid in operation and cleared after receiving
0000
○