Chapter VII Modbus Communication Agreement High Performance Universal FrequConverter User Manual
— 58 —
address space
description
FC
0x0000 ~ 0x1F0A
The correspondence address is a hexadecimal representation. High 8 bits
indicates the group number (00 ~ 1F), and low 8 bits indicates the serial
number within the group (0 ~ 1F). For example: the function code is 10-17,
whose address is 0x 0A11 (0x 0A =10,0x 11=17).
Downtime /
run
Parameter
reading and
writing
0x 1000
Communication
to
set
the
percentage
ratio
of-10000~10000,
corresponding to-100.00~100.00%, negative motor reversal
0x 1001
running frequency
0x 1002
busbar voltage
0x 1003
output voltage
0x 1004
output
0x 1005
output power
0x 1006
output torque
0x 1007
running speed
0x 1008
DI input mode
0x 1009
DO output state
0x 100A
AI1 voltage
0x 100B
AI2 voltage
0x 100C
AI3 voltage
0x 100D
Count the numerical input
0x 100E
Length value input
0x 100F
loading speed
0x 1010
PID set point
0x 1011
PID feedback values
0x 1012
PLC step
0x 1013
HDI Input pulse frequency (input pulse wave frequency) at 0.01R H z
0x 1014
Feedback speed (min / turn, rpm)
0x 1015
Remaining running time (min min)
0x1016
AI1 correction front voltage (0.01V)
0x1017
AI2 correction front voltage (0.01V)
0x1018
AI3 correction front voltage (0.01V)