Chapter V Functional Parameter TableHigh-performance Universal Inverter User Manual
— 22 —
FC
name
description
Factory value
attribute
number setting
04-10
Brake torque limit
number setting
0.0~300.0%
180.0%
○
04-11
Vector
low-frequency
torque
compensation
0.0~100.0%
0.0%
○
04-12
Vector
high-frequency
torque
compensation
0.0~100.0%
0.0%
○
05 Group start-stop control parameters
05-00
starting mode
0: Direct start
1: First, use the DC brake and then start it
2: Speed tracking to start
0
●
05-01
Start frequency
0.00~50.00Hz
0.50Hz
●
05-02
Startup frequency
retention time
00.0~50.0s
0.0s
●
05-03
Start the DC brake
current
0.0~100.0%
0.0%
●
05-4
Start the DC brake
time
0.00~50.00s
0.00s
●
05-05
Add deceleration
mode
0: Straight-line acceleration and deceleration
1: S-curve acceleration and deceleration
0
●
05-06
S-curve
start-segment
acceleration time
0.0~50.0s
0.1s
○
05-07
End time of S
curve
0.0~50.0s
0.1s
○
05-08
Downtime
method
0: Slow down
1: Free shutdown
0
○
05-09
Stop the DC brake
start frequency
0.00~ Maximum frequency
0.00Hz
○
05-10
Stop the DC brake
waiting time
0.00~50.00s
0.00s
○