EN
94
7.5.4 USER menu
In the USER section it’s possible to logout from Web User Interface
and return to the login page, or to access the following sub-menus:
EDIT EMAIL AND PASSWORD
ADMIN PLUS
USER MANAGEMENT
7.5.4.1 EDIT EMAIL AND PASSWORD
In the Edit Email and Password sub-menu you can change the
e-mail and password related to the user which is used to login to
the Web User Interface.
7.5.4.2 ADMIN PLUS
By accessing to the Admin Plus sub-menu you can obtain the
“Admin Plus” user privileges which allow you to:
• View and edit the AC Settings, Reactive Power Control, Ramp
Control, Active Power Control and Frequency Control: P(f) sub-
menus on SETTINGS section.
• Change the grid standard of the inverter, after 24 hours while
the inverter is operating (so the Country Standard sub-menu on
SERVICE TOOLS section was locked).
• Access the “Reset Manufacturing” sub-menu on SERVICE
TOOLS section.
To access on the Web User Interface with the “Admin Plus”
user privileges it’s required to enter a security token that can be
obtained by registering on the website
““Registration website” and “Admin Plus
paragraph for further informations).
7.5.4.3 USER MANAGEMENT
By accessing to the User Management sub-menu it’s possible to
edit all the users already created and create new users (both with
admin or User privileges).
7.5.5 CONNECTIVITY menu
In the CONNECTIVITY section it’s possible to access the following
sub-menus:
LAN
WLAN
RS485
DEBUG SETTINGS
MODBUS
7.5.5.1 LAN
In the LAN sub-menu it’s possible to view the status and change
the daisy chain configuration of the two ethernet ports
(39)
(40)
of the inverter.
• Daisy chain configuration: DHCP or Static:
By selecting the DHCP function (default setup) the router will
automatically assign a dynamic IP address to the inverter
whenever it tries to connect to the user network.
With Static, the user can assign a fixed IP address to the system.
The data which has to be entered in order for IP static address
assigning to take place will appear. Complete the additional fields
at the bottom of the screen (all the fields are mandatory with the
exception of the secondary DNS server).