EN
23
3.5 Technical data
3.5.1 Technical data table PVS-100-TL (standard and S2 models)
PVS-100
Wiring Box version
Standard, S2
Input side
Absolute maximum input voltage (Vmax,abs)
1000 V
Start-up input voltage (Vstart)
420 V (400…500 V)
Operating input voltage range (Vdcmin...Vdcmax)
360…1000 V
Rated input voltage (Vdcr)
620 V
Rated input power (Pdcr)
102000 W
Number of independent MPPT
2 (Parallelable)
MPPT voltage range (VMPPTmin ... VMPPTmax) to Pacr
480…850 V (symmetrical load)
Maximum input power for each MPPT (Pmppt,max)
63000 W
[585 V≤VMPPT≤850 V]
Maximum input current for each MPPT (Idcmax)
108 A
Maximum short circuit current for each MPPT (Iscmax)
(1)
150 A
Maximum return current (AC side vs DC side)
Negligible in normal operating conditions
(6)
Number of input pairs for each MPPT
1
Type of input connectors
4 x M40 cable glands
with M10 Cable lugs
Type of photovoltaic panels that can be connected at input
according to IEC 61730
Class A
Input protection
Reverse polarity protection
Yes, from current limited source
Input over voltage protection for each MPPT-surge arrester (with
monitoring)
Type II
Photovoltaic array isolation control
Yes, according to IEC 62109-2
Residual current monitoring Unit (leakage current protection)
Yes, according to IEC 62109-2
DC switch rating for each MPPT (not available in standard version)
150A - 1000V
Input current monitoring
MPPT level: Standard, S2
Output side
AC Grid connection type
Three phase 3W+PE or 4W+PE (TN system)
Rated Output Power (Pacr @cosφ=1)
100000 W
Maximum Output Power (Pacmax @cosφ=1)
100000 W
Maximum apparent Output power (Smax)
100000 VA
Rated grid Voltage (Vacr)
400 V
Grid voltage range
320...480 V
(4)
Maximum output current (Iac,max)
145 A
Rated Output Frequency (fr)
50 Hz / 60 Hz
Output Frequency Range (fmin...fmax)
45...55 Hz / 55…65 Hz
(5)
Nominal power factor and adjustable range
> 0.995, 0...1 inductive/capacitive with maximum Smax
Total harmonic distortion of current
<3%
Max DC Current Injection (% of In)
< 0.5%*In
Maximum AC cable
185mm
2
Aluminum and copper
AC connection type
Provided bar for lug connections M10
Single core cable glands 4xM40 and 25 or Multi core cable gland
M63 as option
Output protection
Anti-islanding Protection
According to local standard
Maximum external AC overcurrent protection
225 A
Output overvoltage protection - replaceable surge protection device
Type 2 with monitoring
Operating performance
Maximum Efficiency (ηmax)
98.4%
Weighted Efficiency (EURO)
98.2%
Communication
Embedded communication interfaces
1x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz)