![Fimer PVS-100-TL B2 Product Manual Download Page 42](http://html.mh-extra.com/html/fimer/pvs-100-tl-b2/pvs-100-tl-b2_product-manual_2289268042.webp)
EN
42
3.12.2 PVS-100/120-TL B2 version SX, SX2, SY, SY2 models
IN1
+
-
MPPT 1
(DC/DC)
Bulk caps
Inverter
(DC/AC)
Line
filter
L1,S
L2,S
L3,S
N,S
PE
Current reading
OVP monitoring
DSP
DC/DC
IN2
+
-
MPPT 2
(DC/DC)
IN3
+
-
S2-SX2-SY2 version
SX-SY version
and standard version
Inverter power module
1
2
Wiring box
1
2
Communication board
Q1
Alarm
N.C
N.O
C
µP
+ R
GND
Remote control
Ethernet 1 RJ45
RS485/Modbus
+ T/R
- T/R
GND
MPPT 3
(DC/DC)
MPPT 5
(DC/DC)
MPPT 6
(DC/DC)
IN4
+
-
IN5
+
-
IN6
+
-
MPPT 4
(DC/DC)
-SX2/-SY2 version
IN1A(+)
IN1B(+)
IN1D(+)
IN1A(-)
IN1B(-)
IN1D(-)
IN1
IN1C(+)
IN1C(-)
Current
reading
IN2A(+)
IN2B(+)
IN2D(+)
IN2A(-)
IN2B(-)
IN2D(-)
IN2
IN2C(+)
IN2C(-)
IN6
OVP
monitoring
Current
reading
Current
reading
IN3A(+)
IN3B(+)
IN3D(+)
IN3A(-)
IN3B(-)
IN3D(-)
IN3C(+)
IN3C(-)
Current
reading
IN4A(+)
IN4B(+)
IN4D(+)
IN4C(+)
IN4A(-)
IN4B(-)
IN4D(-)
IN4C(-)
Current
reading
IN5A(+)
IN5B(+)
IN5D(+)
IN5C(+)
IN5A(-)
IN5B(-)
IN5D(-)
IN5C(-)
Current
reading
IN6A(+)
IN6B(+)
IN6D(+)
IN6C(+)
IN6A(-)
IN6B(-)
IN6D(-)
IN6C(-)
IN5
IN4
IN3
DC
Switch 1
DC
Switch 2
-SX/-SY version
IN1A(+)
IN1B(+)
IN1D(+)
IN1A(-)
IN1B(-)
IN1D(-)
IN1
IN1C(+)
IN1C(-)
IN2A(+)
IN2B(+)
IN2D(+)
IN2A(-)
IN2B(-)
IN2D(-)
IN2
IN2C(+)
IN2C(-)
IN6
OVP
monitoring
IN3A(+)
IN3B(+)
IN3D(+)
IN3A(-)
IN3B(-)
IN3D(-)
IN3C(+)
IN3C(-)
IN4A(+)
IN4B(+)
IN4D(+)
IN4C(+)
IN4A(-)
IN4B(-)
IN4D(-)
IN4C(-)
IN5A(+)
IN5B(+)
IN5D(+)
IN5C(+)
IN5A(-)
IN5B(-)
IN5D(-)
IN5C(-)
IN6A(+)
IN6B(+)
IN6D(+)
IN6C(+)
IN6A(-)
IN6B(-)
IN6D(-)
IN6C(-)
IN5
IN4
IN3
DC
Switch 1
DC
Switch 2
L1,S
L2,S
L3,S
PE
L1
L2
L3
N,S
N
µP
control
DC/DC
DC/AC
DSP controller
+ R
GND
Remote control 2
Alarm 2
N.C
N.O
C
AC
switch
RS485/Service
Ethernet 2 RJ45
+ T/R
- T/R
GND
L1,S
L2,S
L3,S
PE
L1
L2
L3
N,S
N
DC/AC
DSP controller
DC/DC
DC/AC
DSP controller
DC/AC
DSP
contr.
Control circuit
DSP
DC/DC
contr.
Wi-Fi
S2 version
IN1(+)
IN1(-)
DC
switch
OVP
monitoring
IN2(+)
IN2(-)
IN1(+)
IN2(+)
IN3(+)
IN1(-)
IN2(-)
IN3(-)
IN4(+)
IN5(+)
IN6(+)
IN4(-)
IN5(-)
IN6(-)
Standard version
IN1(+)
IN1(-)
OVP
monitoring
IN2(+)
IN2(-)
IN1(+)
IN2(+)
IN3(+)
IN1(-)
IN2(-)
IN3(-)
IN4(+)
IN5(+)
IN6(+)
IN4(-)
IN5(-)
IN6(-)