7.2.2.3 STEP 3 - Date, Time and Time zone.
• Set the Date, Time and Time zone (The inverter will propose
these fields when available; when it’s not possible for the inverter
to detect the time protocol, these fields have to be manually
entered).
• Click on “Next” button to proceed to the next stage of the
configuration wizard.
7.2.2.4 STEP 4 - Inverter country standard and Input
configuration
• Country standard (selection of grid standard):
Set the grid standard of the country in which the inverter is
installed.
• Input mode:
Parallel or Indipendent mode (parallel mode is only available on
standard and S2 models).
• Confirm the settings by clicking “END”; the inverter will reboot.
NOTE –
D
After the grid standard is set you have 24 hours to
make any changes to the grid standard value; 24 hours later
the Country Standard will be locked. In case of subsequent
needs of change of grid standard, the remaining time shall
be reset in order to have the 24 hours of unlocked operation
available again (refer to
TOOLS menu” sections of Web UI to know how to unlock the
Country Standard).
• A notification will confirm that the wizard is completed.