11
ESP
AÑOL
FRANÇAIS
DEUTSCH
ENGLISH
IT
ALIANO
Once the type of wire has been selected
(using switch 10), the settings page for the
welding wire diameter will appear.
Selecting this option will take you to the
welding screen:
ADJUSTMENTS AND SETTINGS:
Button 10 adjusts the welding settings on the
screen:
Arc length:
Used to vary the basic voltage
used for welding.
Deposit:
Used to modify the deposit of filler
material (wire speed) compared to the
predetermined synergic value.
Inductance:
Used to modify the speed of
variation of the welding current to obtain a
harder arc (low values) or softer arc (high
values.
Double short:
Used to activate (ON) or
deactivate (OFF) the mode at two levels, in
other words the continual switching between
two different levels of welding current
L1 span:
When the two level mode is active
this function is used to set the duration of the
first current level.
L2 span
: When the two level mode is active
this function is used to set the duration of the
first current level.
L2 amplitude:
When the two level mode is
active this function is used to set the second
current level (L2) compared to the current set
(level L1)
L2 voltage:
When the two level mode is
active this function is used to modify the
voltage of the second level (L2)
independently of the voltage of the L1 level
(arc length parameter)
2t-4t-4bilevel:
Used to set the operating
mode to 2 times or 4 times.
2t:
In 2 time operating mode the machine
welds for the entire time the torch button is
held down.
4t:
In 4 time operating mode pressing the
torch button once starts the weld and
pressing it a second time ends the weld.
4bi:
This operation is similar to the 4t mode
with the only difference that pressing the
torch button for short periods (< 1s) during
welding causes the passage of the current
from the first level I1 to the second level I2;
holding the button down (> 1s) causes the
start of the end of the weld.
2nd level:
used to set the value of the
current relative to the second power level,
active when the value of the 2t-4t-4bilevel
parameter is set to 4bi.
Start/End level:
Used to activate (ON) or
deactivate (OFF) the mode with the initial
and final current.
Start level:
Used to set the initial value as a
percentage of the welding current (e.g. 130%
implies Is=1,30xI1)
Start level time:
Used in 2t mode to set the
time the initial current ls is applied
Ls->l1 slope:
Used to set the duration of the
current ramp from the initial level Is to the
welding current I1.
L1->le slope:
Used to set the duration of the
current ramp from the welding current I1 to
the final level Ie.
START
BACK
OPTIONS
0,6mm
0,8mm
1,0mm
1,2mm
Select wire diameter
MIG-MAG
S.A.S.
Fe
Ready to weld
START
BACK
MEM +
OPTIONS
80
A
23,2
V
>
MIG-MAG
S.A.S.
Fe
0,6mm
arc lenght
deposit
inductance
double short
L1 span
L2 span
L2 amplitude
L2 voltage
2s-4s-4bilevel
2nd level
start/End level
Start level
Start level time
Ls->L1 slope
L1->Le slope
End level
End level time
spot welding
pause
pre gas time
post gas time
burnback
soft start
hot start
water pump
0,0v
0,0m/’
0
OFF
0,3s
0,3s
60%
0,0v
2t
80%
OFF
125%
0,0s
0,0s
0,0s
80%
0,0s
0,0s
0,0 s
0,1 s
2,0 s
0,0 s
0
0
OFF
10,5m/'
1,8mm
Summary of Contents for King 320
Page 2: ......
Page 3: ...KING 320 ...
Page 4: ...TARGA DATI NOMINAL DATA LEISTUNGSCHILDER PLAQUE DONÉES PLACA DE CARACTERÌSTICAS ...
Page 34: ...2 WARNING SYMBOLS ...
Page 35: ...3 ...
Page 36: ...4 ...
Page 62: ...2 VERWENDETE SYMBOLE ...
Page 63: ...3 ...
Page 64: ...4 ...
Page 90: ...2 SYMBOLES UTILISÉS ...
Page 91: ...3 ...
Page 92: ...4 ...
Page 118: ...2 SÌMBOLOS UTILIZADOS ...
Page 119: ...3 ...
Page 120: ...4 ...
Page 145: ...NOTE ...
Page 146: ...NOTE ...
Page 147: ......
Page 148: ......